TopChiller can design and manufacture all types of hydroponic water chillers for you
- Cooling capacity ranges up to 60 Ton
- Temperature control ranges 18°C to 26°C
- Hermetic scroll compressor installation
- Freon free refrigerant & horsepower
- Titanium evaporator & heat exchanger
- Auto protection system & control system
- Large refrigeration capacity, quiet operation
- Fresh water and saltwater installation
Your Professional Hydroponic Water Chiller Manufacturer and Supplier Over 20 Years
Hydroponic Water Chiller is a cooling machine designed for a water-based irrigation system, provides a cooling effect to growing plants by chilled water circulation.
Hydroponic plants grow at a lower temperature like rooted soil plants adapted to lower root temperature. The temperature requirements of hydroponic plants are fulfilled by Hydroponic Water Chiller.
TopChiller is a certified company in China that is diligently working to manufacture energy-efficient Hydroponic Water Chiller for the last twenty years.
TopChiller is the most trusted company working at the international level to vast the hydroponic irrigation system and enhance plant products by manufacturing Hydroponic Water Chiller and successfully supplied it to all world marketplace since 1991.
Hydroponic Water Chiller made by TopChiller consists of scroll compressor, titanium heat exchanger, water tank, titanium evaporator, water pump, auto protection system, power supply, control system, refrigeration circuit, and Freon free refrigerant.
TopChiller brand Hydroponic Water Chiller has different benefits in hydroponic irrigation system as given below:
- Hydroponic Water Chiller ensures the regular and efficient growth of hydroponic plants configured by constant chilled water circulation through unit coils around the irrigation system providing a chilling effect.
- TopChiller designed Hydroponic Water Chiller is featured with fresh water and salts water installation, maintains the nutrient level inside water solution provided to water growing plants by specialized control systems and temperature controlling system.
- By providing constant chilled water, Hydroponic Water Chiller kills the insects and stops microbial growth that is sensitive to cooling effect and ultimately prevents the plant from microbes to enhance the product.
- TopChiller designed Hydroponic Water Chiller ensures efficient performance featured by titanium coated heat exchanger and evaporator preventing corrosion and environmental hazards.
- Hydroponic Water Chiller is configured with air filters that maintain the filtration of water, preventing the entrance of extra salts in water circulation and ensuring water tank longer service life by removing all clogging material outside the system.
- TopChiller brand Hydroponic Water Chiller regulates the temperature of the water as well nutrients temperature required for plant growth precisely with easy installation.
Hydroponic Water Chiller has used for Hydroponic based applications as:
Grower houses, DWC, aeroponics, aquariums, greenhouses, hydroponic gardens, hydroponic irrigation, etc.
If you are thinking to enhance plant production in soil scarce areas and want to buy a Hydroponic Water Chiller for your application?
If You are planning to come in contact with a Hydroponic Water Chiller manufacturing company having standardized credibility to grow up your business?
No need to move anywhere. TopChiller is a highly preferred company that fully supports Hydroponic systems. Make contact with TopChiller experts and customize a Hydroponic Water Chiller best suited to your application at smart rates.
The TopChiller team is waiting for your response. Our team will satisfy you and clear all queries regarding Hydroponic Water Chiller working and installation.
- Data Sheet
- Image Gallery
- Main Parts
- Video
Hydroponic Water Chiller Technical Specifications | ||||||||||||||
Items Model | AC-0.5A | AC-1A | AC-1.5A | AC-2A | AC-2.5A | AC-3A | AC-4A | AC-5A | AC-6A | AC-8AD | AC-10AD | AC-12AD | AC-15AD | |
Cooling capacity | Kcal/h 50HZ/60HZ | 1419 | 2451 | 3182 | 4833 | 5848 | 7181 | 9288 | 11988 | 14534 | 18576 | 23994 | 29068 | 38270 |
1703 | 2941 | 3784 | 5800 | 7018 | 8617 | 11146 | 14386 | 17441 | 22291 | 28793 | 34882 | 45924 | ||
KW 50HZ/60HZ | 1.65 | 2.85 | 3.7 | 5.62 | 6.8 | 8.35 | 10.8 | 13.94 | 16.9 | 21.6 | 27.9 | 33.8 | 44.5 | |
1.98 | 3.42 | 4.4 | 6.74 | 8.2 | 10.02 | 12.96 | 16.73 | 20.28 | 25.92 | 33.48 | 40.56 | 53.4 | ||
Input power | KW | 0.88 | 1.35 | 2 | 2.25 | 2.66 | 3.27 | 4.07 | 5.75 | 6.45 | 8.25 | 11.5 | 12.9 | 17.45 |
Max Current | A | 5.4 | 8.2 | 12 | 13.6 | 6.6 | 8.2 | 10.1 | 13.8 | 15.5 | 20 | 27.9 | 31.3 | 42.4 |
Power source | 1PH~220V/3PH~220V/380V 50HZ/60HZ | 3PH~380V/415V/480V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) | ||||||||||||
Refrigerant | Type | R22/R407C/134a/404A/410A | ||||||||||||
Control | Capillary / thermostatic expansion valve | |||||||||||||
Compressor | Type | Hermetic Rotary | Hermetic scroll ( piston ) | |||||||||||
Power(KW) | 0.45 | 0.89 | 1.3 | 1.73 | 2.1 | 2.7 | 3.5 | 4.55 | 5.25 | 3.5×2 | 4.55×2 | 5.25×2 | 7×2 | |
Condenser | Type | Efficient finned copper tube with aluminum+low noise external rotor fan | ||||||||||||
Air flow (m3/h) | 750 | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | |
Air blower(KW) | 0.06 | 0.09 | 0.15 | 0.15 | 0.19 | 0.14×2 | 0.14×2 | 0.19×2 | 0.19×2 | 0.25×2 | 0.45×2 | 0.45×2 | 0.6×2 | |
Evaporator | Type | SS Tank coil / shell and tube type / Plate type heat exchanger | ||||||||||||
Chilled water (m3/h) | 0.28 | 0.49 | 0.64 | 0.97 | 1.12 | 1.44 | 1.86 | 2.4 | 2.91 | 3.71 | 4.8 | 5.81 | 7.65 | |
0.34 | 0.59 | 0.76 | 1.16 | 1.4 | 1.72 | 2.23 | 2.88 | 3.49 | 4.46 | 5.76 | 7 | 9.18 | ||
Water tank(L) | 10.6 | 18.3 | 27 | 27 | 50 | 50 | 60 | 60 | 110 | 120 | 200 | 200 | 270 | |
Inlet/outlet pipe (inch) i | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1″ | 1″ | 1″ | 1″ | 1″ | 1-1/2″ | 2″ | 2″ | 2″ | |
Water pump | Power (kw) | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 |
Max lift(m) | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 30 | 30 | 25 | 25 | 25 | 28 | |
Max flow (m3) | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 8.1 | 8.1 | 8.1 | 13.5 | 13.5 | 25.2 | |
Safety protection | Compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection, exhaust overheat protection | |||||||||||||
Dimension | L(mm) | 550 | 550 | 600 | 600 | 720 | 980 | 980 | 1150 | 1150 | 1350 | 1500 | 1500 | 1860 |
W(mm) | 350 | 450 | 500 | 500 | 550 | 520 | 520 | 560 | 560 | 680 | 760 | 760 | 850 | |
H(mm) | 695 | 845 | 985 | 985 | 1350 | 1170 | 1170 | 1215 | 1215 | 1530 | 1660 | 1660 | 1900 | |
Net weight(KG) | 45 | 62 | 85 | 95 | 125 | 152 | 175 | 185 | 215 | 283 | 345 | 382 | 580 | |
Note: The above specifications are according to the following design conditions: 1, 12℃/7℃.Chilled water inlet/outlet temperature 12℃/7℃. 2, 33℃/38℃.Cooling air inlet/outlet temperature 33℃/38℃. We reserve the right to modify the specification without further notice. |
Hydroponic Water Chiller Technical Specifications | |||||||||||||
Items Model | AC-15AT | AC-20AD | AC-20AF | AC-25AD | AC-25AF | AC-30AD | AC-30AT | AC-40AD | AC-40AF | AC-50AD | AC-50AF | AC-60AD | |
Cooling capacity | Kcal/h 50HZ/60HZ | 36120 | 49966 | 47988 | 58480 | 58136 | 74734 | 74922 | 98040 | 99760 | 119024 | 116960 | 144996 |
43344 | 59959 | 57586 | 70176 | 69763 | 89681 | 89990 | 117648 | 119712 | 142829 | 140352 | 173995 | ||
KW 50HZ/60HZ | 42 | 58.1 | 55.8 | 68 | 67.6 | 86.9 | 87.2 | 114 | 116 | 138.4 | 136 | 168.6 | |
50.4 | 69.72 | 66.96 | 81.6 | 81.12 | 104.28 | 104.64 | 136.8 | 139.2 | 166.08 | 163.2 | 202.3 | ||
Input power | KW | 17.1 | 21.73 | 22 | 25.4 | 24.8 | 33.39 | 33.1 | 44.91 | 43.3 | 57.3 | 54 | 65 |
Max Current | A | 43.2 | 52.7 | 53.3 | 63.7 | 61.3 | 81 | 80.2 | 109 | 106 | 135.5 | 128.5 | 135 |
Power source | 3PH~380V/415V/480V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) | ||||||||||||
Refrigerant | Type | R22/R407C/134a/404A/410A | |||||||||||
Control | Capillary / Thermostatic expansion valve | ||||||||||||
Compressor | Type | Hermetic scroll ( piston ) | |||||||||||
Power(KW) | 4.55×3 | 8.96×2 | 4.55×4 | 10.8×2 | 5.25×4 | 13.62×2 | 8.96×3 | 18.78×2 | 8.96×4 | 23.6×2 | 10.8×4 | 27.4×2 | |
Condenser | Type | Efficient finned copper tube with aluminum+low noise external rotor fan | |||||||||||
Air flow (m³/h) | 15000 | 20000 | 20000 | 25000 | 25000 | 30000 | 30000 | 40000 | 40000 | 50000 | 50000 | 60000 | |
Air blower(KW) | 0.6×2 | 0.78×2 | 0.78×2 | 0.78×2 | 0.78×2 | 0.42×6 | 0.42×6 | 0.6×6 | 0.6×6 | 0.78×6 | 0.78×6 | 0.78×6 | |
Evaporator | Type | SS Tank coil/ shell and tube type/Plate type heat exchanger | |||||||||||
Chilled water (m³/h) | 7.22 | 10 | 9.6 | 11.69 | 11.62 | 14.94 | 15 | 19.6 | 19.95 | 23.8 | 23.4 | 29 | |
8.67 | 11.99 | 11.51 | 14.03 | 13.95 | 17.93 | 18 | 23.52 | 23.94 | 28.6 | 28.1 | 34.8 | ||
Water tank(L) | 270 | 350 | 350 | 350 | 350 | 420 | 420 | 580 | 580 | 580 | 580 | 580 | |
inlet/outlet pipe (inch) | 2″ | 2″ | 2″ | 2-1/2″ | 2-1/2″ | 2-1/2″ | 2-1/2″ | 3″ | 3″ | 3″ | 3″ | 3″ | |
Water pump | Power(kw) | 2.2 | 2.2 | 2.2 | 2.2 | 2.2 | 4 | 4 | 4 | 4 | 5.5 | 5.5 | 5.5 |
Max lift(m) | 28 | 28 | 28 | 28 | 28 | 30 | 30 | 30 | 30 | 32 | 32 | 32 | |
Max flow (m³) | 25.2 | 25.2 | 25.2 | 25.2 | 25.2 | 36 | 36 | 36 | 36 | 40 | 40 | 40 | |
Safety devices | Compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection, exhaust overheat protection | ||||||||||||
Dimension | L(mm) | 1860 | 2020 | 2020 | 2020 | 2020 | 2200 | 2200 | 2350 | 2350 | 2600 | 2600 | 2600 |
W(mm) | 850 | 950 | 950 | 950 | 950 | 1150 | 1150 | 1350 | 1350 | 1500 | 1500 | 1500 | |
H(mm) | 1900 | 2000 | 2000 | 2000 | 2000 | 1980 | 1980 | 2000 | 2000 | 2100 | 2100 | 2100 | |
Net weight(KG) | 580 | 650 | 650 | 810 | 810 | 890 | 890 | 1112 | 1112 | 1320 | 1320 | 1320 | |
Note: The above specifications are according to the following design conditions: 1, Chilled water inlet/outlet temperature 12℃/7℃. 2, Cooling air inlet/outlet temperature 33℃/38℃. We reserve the right to modify the specification without further notice. |