TopChiller can design and manufacture all types of ice rink chillers for you
- Cooling capacity ranges from 30 ton to 200 ton
- Temperature control ranges from 26°Fto 28°F
- Superb quality branded screw compressor
- Plate & frame evaporator with glycol installation
- The built-in system, factory mounted testation
- Condenser fans & glycol circulation pump
- Heat recovery featuring & efficient motor
- Protecting devices and control panels
Your Ice Rink Chiller Manufacturer and Supplier Over 20 Years
Ice Rink Chiller is a refrigeration-based cooling device that is used to maintain the chilled temperature of the ice rink at low temperature by using glycol circulation.
TopChiller is the most reputed and appreciated company of China that is manufacturing Ice Rink Chiller and supplying successfully to all over the world by keeping in view the requirements of customers since 1999.
By providing easy and quality assured certifications about the manufacturing of Ice Rink Chiller, TopChiller has earned a credible reputation and recognition among world-famous companies and stakeholders.
Screw compressor, air/water-cooled condenser, plate type heat exchanger, refrigeration tanks, pipelines and coils, power supply connection, protection devices, expansion valves are the best reliable components used for Ice Rink Chiller manufacturing.
TopChiller brand Ice Rink Chiller is famous for chilling purposes with a variety of benefits as given below:
- Ice Rink Chiller is highly reliable and precise in its performance for providing chilled temperature to Ice Rink stabilizing playing performance configured by the installation of double or triple compressor system for high compression and consistent cooling.
- TopChiller brand Ice Rink Chiller is highly versatile in its performance customizing ice rink temperature according to hockey players or skaters configured by air-cooled or water-cooled condensers with high load capacity exchanging heat with the ambient environment.
- Ice Rink Chiller maintains the rink at a specific temperature featured by a continuous discharge of heat and humidity from the rink by brine solution as refrigerant, as brine solution act as anti-freezing for its consistent flow.
- TopChiller designed Ice Rink Chiller is easy to install due to its compact size occupying lower space configured by the installation of plate and frame type heat exchanger, ensuring exchange of heat by walls of plates from rink to unit.
- Ice Rink Chiller has factory mounted testation preventing the owner from extra expenses of unit maintenance and installation.
Ice Rink Chiller is used for different applications requiring lower temperature chilling features as given below:
Hockey skating rink, Olympic rink, curling, skating applications implementation for green world system, ice hockey, figure skating, and speed skating, etc.
If you are reflecting over to find the best optimal solution providing Ice Rink Chiller for your application requiring temperature in minus?
If you are intended to search for an Ice Rink Chiller manufacturer company in China famous for its collaboration with customers for your business development?
TopChiller is offering the best services for chilling. So don’t be hesitated and contact us about the price. TopChiller technocrats and experts are providing customized intuition to customers for selecting a reasonable Ice Rink Chiller according to application requirements.
Our technocrats are trained to get specification details about client application and then make a supportive decision of chiller selection accordingly.
- Data Sheet
- Image Gallery
- Main Parts
- Video
Ice Rink Chiller Technical Specification
Model/Items | Temp. | TPL-3AL | TPL-5AL | TPL-6AL | TPL-8AL | TPL-10AL | TPL-12AL | TPL-15AL | TPL-20AL | TPL-25AL | TPL-30AL | TPL-40AL | ||
Cooling Capacity | KW 50HZ/60HZ | -10℃ | 3.80 4.60 | 6.30 7.60 | 7.50 9.00 | 9.10 10.90 | 13.20 15.80 | 16.10 19.30 | 19.50 23.40 | 26.40 31.70 | 32.20 38.60 | 39.00 46.80 | 52.00 62.40 | |
-20℃ | 1.90 2.30 | 3.00 3.60 | 4.00 4.80 | 6.00 7.20 | 7.10 8.50 | 8.00 9.60 | 13.90 16.70 | 16.90 20.30 | 20.80 25.00 | 24.40 29.30 | 30.80 37.00 | |||
-30℃ | 1.00 1.20 | 1.60 1.90 | 1.90 2.30 | 2.70 3.20 | 3.20 3.80 | 3.80 4.60 | 6.10 7.30 | 9.50 11.4 | 12.10 14.50 | 14.30 17.10 | 19.00 22.80 | |||
-35℃ | 0.67 0.80 | 1.04 1.25 | 1.50 1.80 | 2.30 2.80 | 2.80 3.40 | 3.00 3.60 | 4.30 5.20 | 6.35 7.62 | 8.30 10.00 | 10.10 12.10 | 13.35 16.00 | |||
Evaporator | Chilled Water (m³/h) | -10℃ | 0.65 0.79 | 1.10 1.30 | 1.30 1.50 | 1.60 1.90 | 2.30 2.70 | 2.80 3.30 | 3.40 4.10 | 4.50 5.40 | 5.60 6.70 | 6.70 8.10 | 9.00 10.80 | |
-20℃ | 0.33 0.40 | 0.52 0.62 | 0.69 0.83 | 1.10 1.30 | 1.23 1.47 | 1.38 1.65 | 2.39 2.87 | 2.85 3.45 | 3.57 4.30 | 4.20 5.04 | 5.30 6.36 | |||
-30℃ | 0.17 0.21 | 0.28 0.33 | 0.33 0.40 | 0.47 0.55 | 0.55 0.65 | 0.65 0.80 | 1.10 1.30 | 1.60 2.00 | 2.10 2.50 | 2.46 2.90 | 3.30 3.90 | |||
-35℃ | 0.12 0.14 | 0.18 0.22 | 0.26 0.31 | 0.40 0.48 | 0.48 0.58 | 0.52 0.62 | 0.72 0.89 | 1.10 1.31 | 1.43 1.72 | 1.74 2.09 | 2.30 2.76 | |||
Type | Shell and tube type/Plate type heat exchanger | |||||||||||||
Inlet/outlet pipe | lnch | 1″ | 1″ | 1″ | 1″ | 1-1/2″ | 1-1/2″ | 2″ | 2″ | 2″ | 2-1/2″ | 2-1/2″ | ||
Input power | KW | 3.18 | 4.86 | 5.61 | 7.25 | 9.4 | 10.9 | 13.5 | 18.8 | 22.55 | 28.5 | 37.5 | ||
Max Current | A | 7.8 | 12 | 13.7 | 18 | 23 | 26.5 | 33 | 46 | 55 | 69 | 91 | ||
Power Source | 3PH~380V/415V/480V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) | |||||||||||||
Refrigerant | Type | R22(R404A/R507) | ||||||||||||
Control | z | |||||||||||||
Compressor | Type | Hermetic scroll ( piston ) | ||||||||||||
Power | KW | 2.25 | 3.75 | 4.5 | 6 | 7.5 | 9 | 11.3 | 7.5*2 | 9.37*2 | 11.3*2 | 30 | ||
Condenser | Type | Efficient finned copper tube with aluminum + low noise external rotor fan | ||||||||||||
Water pump | Power | KW | 0.75 | 0.75 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 4 | 5.5 | |
Max lift | m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 20 | ||
Safety protection | Compressor inner protection, over current protection, high / low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti freezing protection | |||||||||||||
Dimension | Length | mm | 980 | 1150 | 1150 | 1350 | 1500 | 1500 | 1860 | 2020 | 2020 | 2200 | 2350 | |
Width | mm | 520 | 560 | 560 | 680 | 760 | 760 | 850 | 950 | 950 | 1150 | 1350 | ||
Height | mm | 1170 | 1215 | 1215 | 1530 | 1660 | 1660 | 1900 | 2000 | 2000 | 1980 | 2000 | ||
Net weight(KG) | Kg | 135 | 165 | 210 | 310 | 450 | 530 | 750 | 835 | 920 | 1080 | 1125 | ||